If you have noticed the pressure gauge on your boiler dropping, or your boiler keeps showing a low pressure warning, you are not alone. Low boiler pressure is one of the most common heating problems we are called out to, and in many cases the cause is straightforward. Here is what is happening and what to do about it.

What is boiler pressure?

Your boiler runs on a sealed system of water under pressure. This pressure allows water to circulate around your radiators and pipes efficiently. Most boilers should sit at around 1 to 1.5 bar when the heating is off. If the gauge drops below 1 bar, the boiler may struggle to work properly or shut down entirely as a safety measure.

Common causes of pressure loss

1. A water leak somewhere in the system

The most common cause of ongoing pressure loss is a small leak somewhere in the system, such as at a radiator valve, a pipe joint or the boiler itself. Even a tiny leak you cannot easily see will gradually let pressure escape. Check around radiators and visible pipework for damp patches or staining.

2. Bleeding radiators

If you have recently bled your radiators to release trapped air, this releases some water from the system and can lower the pressure. This is normal, and topping the pressure back up usually solves it.

3. A faulty pressure relief valve

The pressure relief valve releases water if the system pressure gets too high. If this valve becomes faulty or stuck, it can let water escape continuously, causing the pressure to drop. You may notice water dripping from the small pipe that exits through an outside wall.

4. A failed expansion vessel

The expansion vessel absorbs the increase in pressure as water heats up and expands. If it fails, you may see the pressure swing dramatically between hot and cold, and the relief valve may discharge. This requires an engineer to re-pressurise or replace the vessel.

How to top up your boiler pressure

If the pressure is simply low and there is no obvious leak, you can usually top it up yourself using the filling loop, a small flexible hose beneath the boiler:

  • Turn the boiler off and let it cool
  • Locate the filling loop beneath the boiler
  • Open both valves slowly to let cold water into the system
  • Watch the gauge and close the valves once it reaches around 1.5 bar
  • Turn the boiler back on

If you are unsure, check your boiler manual or call a Gas Safe registered engineer. Never force any valves.

When to call an engineer

Topping up the pressure is a short-term fix. If you find yourself doing it repeatedly, that points to an underlying fault that needs investigating. Call an engineer if:

  • The pressure keeps dropping after you top it up
  • You can see water leaking from the boiler or pipework
  • The pressure relief pipe outside is dripping
  • You are not comfortable topping up the pressure yourself